Does a skylight need a screen under the glass?
Only for some glass, says the home code. Tempered or heat strengthened skylight glass needs a broken glass screen under its full area, unless it qualifies for an exception. Laminated glass with the right interlayer needs no screen, and small tempered panes low enough overhead can go without one too.
- Free estimates
- Open 24/7
- Hablamos español
What the code says
The International Residential Code covers this in sections R308.6.3 to R308.6.5 of chapter 3.
- Needs a screen: fully tempered or heat strengthened glass, single or the inboard pane.
- No screen: laminated glass meeting the interlayer rule.
- Small tempered: 16 square feet or less, top 12 feet or less above the floor, 3/16 inch thick at most.
- Large tempered: within 30 degrees of vertical, top 10 feet or less above the floor.
In multiple glazing, an inboard pane of wired glass needs a screen as well.
In a double pane skylight
The rule looks at the inboard pane, the one facing the room. If it is tempered, heat strengthened or wired glass, the screen goes in unless an exception applies. Choosing a laminated inboard pane removes the need for a screen. The other panes can be any glass on the skylight list.