Can a door with panic hardware also have an electric lock?

Yes. The building code allows door hardware release of electric locks, and where panic or fire exit hardware is required, operating that hardware must also release the electric lock. The hardware must work with one hand, have an obvious method of operation in any lighting, and cut power to the lock so the door unlocks immediately.

What the rule says

The 2021 International Building Code covers this in section 1010.2.11 of chapter 10.

  • One hand: operable with one hand and one motion.
  • Obvious: readily operated under all lighting conditions.
  • Immediate: cuts power to the lock and unlocks the door at once.
  • Power loss: unlocks the door.
  • Listing: locking system units listed to the access control standard.

Retrofits on glass doors

Adding an electric lock to an existing glass door often means a new panic device with a release switch built in, or new hardware in the top rail. Glass doors with narrow rails have limited room, so measure the rail before ordering hardware.