Can a glass door have a magnetic lock?
Yes, under the building code’s rules for electrically locked egress doors, in any occupancy except high hazard Group H. The lock must release from hardware on the door or from a sensor that detects someone approaching, and it must unlock automatically if power to the lock is lost.
- Free estimates
- Open 24/7
- Hablamos español
What the rule says
The 2021 International Building Code covers this in section 1010.2.11 and 1010.2.12 of chapter 10.
- Door hardware release: hardware on the door cuts power to the lock and unlocks it at once.
- Sensor release: a sensor on the egress side unlocks the door as someone approaches.
- Power loss: unlocks the door either way.
- Listing: the locking system units must be listed to the national access control standard.
- Not allowed: in Group H occupancies.
On a glass door, a mag lock usually mounts at the top of the frame, with an armature plate on the door.
Choosing the release
Door hardware release suits doors people push, since the bar or lever itself unlocks the door. Sensor release needs a push to exit button near the door as a backup. Either way, check the lock during a power cut and a fire alarm test.
Read what to do when storefront glass breaks overnight, or see commercial glass door repair for a free estimate.
We serve Northern Virginia, the Maryland suburbs and Washington, DC.
Related questions
- Where does a push to exit button go?
- What happens to an electric door lock in a power outage?
- Do electric door locks have to release on a fire alarm?
- Can a door with panic hardware also have an electric lock?
- What is a delayed egress lock?
- Does an automatic door have to open in a power failure?