Open 24/7Licensed in VirginiaInsured and bonded

Call (202) 600-6220

Can a revolving door or air curtain replace a vestibule?

A revolving door is exempt from the vestibule rule, but any doors next to it still need a vestibule. A door with an air curtain also qualifies if the air reaches at least 6.56 feet per second at the floor, it was tested to the national air curtain standard and it runs with the door.

What the rule says

The commercial part of the International Energy Conservation Code covers this in section C402.5.9 of chapter 4.

  • Revolving doors: exempt from the vestibule rule.
  • Doors beside them: still need a vestibule.
  • Air curtain speed: 6.56 feet per second at the floor, at least.
  • Air curtain controls: manual or automatic, working as the door opens and closes.
  • Installation: to the air curtain maker’s instructions.

Revolving doors also have their own air leakage limit of 1.00 cfm per square foot.

Planning an entrance

If a revolving door is the main entrance and a swing door beside it serves strollers and wheelchairs, the swing door is the one that needs the vestibule. Accessible routes have their own rules for revolving doors, so a swing door is usually part of the plan.

Read what to do when storefront glass breaks overnight, or see commercial glass door repair for a free estimate.

Commercial entrance glass to replace?

Send us a photo for a free estimate, or call (202) 600-6220.