Does a store entrance need a vestibule?
Usually, yes. Outside climate zones 0 to 2, the commercial energy code requires an enclosed vestibule at building entrances. Every door into and out of it must be self closing, and it must be laid out so the inner and outer doors don’t have to be open at the same time.
- Free estimates
- Open 24/7
- Hablamos español
What the rule says
The commercial part of the International Energy Conservation Code covers this in section C402.5.9 of chapter 4.
- Where: building entrances in climate zones 3 to 8, including Northern Virginia.
- Doors: self closing, in and out of the vestibule.
- Layout: deep enough that both doors need not be open at once.
- Exceptions: small spaces, staff only doors, dwelling doors, revolving doors, service doors and air curtains.
The vestibule holds conditioned air in as people come and go.
Vestibule glass and doors
Most vestibules are glass on both sides, so they are part of the storefront. The doors still have to meet the entrance door U-factor and air leakage limits, and the closers must bring each door shut on its own. A closer that no longer closes the door fully works against the rule.
Read what to do when storefront glass breaks overnight, or see commercial glass door repair for a free estimate.
Related questions
- Does a small shop need a vestibule?
- Can a revolving door or air curtain replace a vestibule?
- How much air can storefront glass leak?
- How much air can a commercial glass entrance door leak?
- Do storm windows or window film on a commercial building have to meet the energy code?