Open 24/7Licensed in VirginiaInsured and bonded

Call (202) 600-6220

How much air can a commercial glass entrance door leak?

Commercial glazed swinging entrance doors can leak up to 1.00 cfm per square foot under the commercial energy code. The same limit covers power operated sliding and folding doors and revolving doors. Ordinary swinging and sliding doors are held to 0.20.

What the rule says

The commercial part of the International Energy Conservation Code covers this in Table C402.5.4 of chapter 4.

  • Glazed swinging entrance doors: 1.00.
  • Power sliding and folding doors: 1.00.
  • Revolving doors: 1.00.
  • Ordinary swinging and sliding doors: 0.20.
  • Garage doors: 0.40.
  • Rolling and high speed doors: 1.00 and 1.30.

As with windows, each door assembly must be tested by an accredited, independent lab and labeled by its maker.

Keeping a door tight

Weatherstripping, sweeps and the closer all affect how much air gets past a door once it is in use. A door that sags, drags or no longer latches leaves gaps along the edges, so adjust or repair it when the glass or hardware is serviced.

Read what to do when storefront glass breaks overnight, or see commercial glass door repair for a free estimate.

Commercial door not closing right?

Send us a photo for a free estimate, or call (202) 600-6220.