Does a small shop need a vestibule?
Not if the entrance door opens directly from a space of less than 3,000 square feet. The commercial energy code also exempts doors not meant for the public, such as staff only and equipment room doors, and doors that open straight from a dwelling unit or sleeping unit.
- Free estimates
- Open 24/7
- Hablamos español
What the rule says
The commercial part of the International Energy Conservation Code covers this in section C402.5.9 of chapter 4.
- Small spaces: doors opening directly from a space under 3,000 square feet.
- Staff doors: doors meant only for employees.
- Equipment rooms: doors to mechanical or electrical rooms.
- Homes and rooms: doors opening from a dwelling or sleeping unit.
- Warm climates: all of zones 0 to 2.
A shop in a larger building can still need a vestibule if its door opens from a large lobby or mall area.
Measuring the space
The test is the area of the space the door opens from, not the size of the building. A shop 40 feet by 70 feet is 2,800 square feet, just under the line. One 50 by 70 feet, at 3,500 square feet, would need a vestibule unless another exception applies.
Read what to do when storefront glass breaks overnight, or see commercial glass door repair for a free estimate.
Related questions
- Does a store entrance need a vestibule?
- Can a revolving door or air curtain replace a vestibule?
- How much air can storefront glass leak?
- How much air can a commercial glass entrance door leak?
- Do storm windows or window film on a commercial building have to meet the energy code?
- All glass repair questions
From other topics
- Do glass office partitions need a permit in Fairfax County? (permits for a new shop layout)
Shop door glass to replace?
Send us a photo for a free estimate, or call (202) 600-6220.