How tall does a commercial door have to be?
At least 80 inches of clear opening height, under the building code rule for doors on the way out of a building. Door closers, overhead stops, power operators and magnetic locks are allowed a little lower, down to 78 inches above the floor. The same rule asks for at least 32 inches of clear width.
- Free estimates
- Open 24/7
- Hablamos español
What the code says
The International Building Code sets door sizes in section 1010.1.1 of chapter 10.
- Height: 80 inches clear at least.
- Width: 32 inches clear, measured from the face of the open door to the stop, with the door at 90 degrees.
- Below 34 inches: nothing may stick into the clear width.
- From 34 to 80 inches: nothing may stick in more than 4 inches.
- Hardware overhead: closers, stops, operators and magnetic locks may sit at 78 inches.
Checking the hardware
When a closer or overhead stop is replaced, measure from the finished floor to the lowest point of the new arm or body. It should read 78 inches or more. A magnetic lock or power operator added later follows the same limit.
If a storefront door was broken, read what to do first, or see door closer repair for a free estimate.
Related questions
- How hard should an exterior commercial door be to open?
- Does a commercial door need a landing on both sides?
- Can a sliding door be a commercial exit?
- Can a commercial exit door have two locks?
- Are flush bolts allowed on commercial double doors?
- All glass repair questions
From other topics
- How wide does a commercial door have to be? (the width rule)
- How big does a front door have to be? (the rule for houses)
Closer hanging low or leaking?
Send us a photo for a free estimate, or call (202) 600-6220.