How hard should an exterior commercial door be to open?

The building code allows no more than 30 pounds of force to start an exterior swinging door moving, and no more than 15 pounds to push it fully open. The same limits cover sliding, folding and fire rated doors. Manual interior swinging doors that are not fire rated have a lower limit of 5 pounds.

What the code says

The International Building Code sets door forces in section 1010.1.3 of chapter 10.

  • Start moving: 30 pounds at most for exterior, sliding, folding and fire rated doors.
  • Fully open: 15 pounds at most for the same doors.
  • Interior swinging doors: 5 pounds at most, unless fire rated.
  • Unlatching by push or pull: 15 pounds at most.
  • Unlatching by turning: 28 inch pounds at most.

The code counts the force to release the latch apart from the force to swing the door open.

When a door takes more force

A closer set too strong, worn hinges or pivots, or a door rubbing its frame can all add force. Have the door checked before the latch or hinges fail.