Do replacement windows need window opening control devices?

Sometimes. The existing building code calls for window opening control devices when an operable window is replaced and the new window’s opening sits less than 24 inches above the floor in a house and more than 72 inches above the ground outside. It also applies only if a 4 inch ball would pass.

What the code says

The International Existing Building Code covers this in section 702.4 of chapter 7.

  • Which windows: operable windows replaced with sash and frame, or sash only.
  • Height inside: under 24 inches above the floor in houses and townhouses, under 36 inches in apartments.
  • Height outside: more than 72 inches down to grade or the surface below.
  • Opening: the window opens wide enough to pass a 4 inch ball.

The rule covers houses and townhouses under the home code, and apartment buildings with dwelling units.

Bedroom escape windows

A control device can go on a bedroom escape window, but once released it must let the window open fully, and the window must work from inside without keys or tools. The device itself must meet the national standard for window opening control devices.