Open 24/7Licensed in VirginiaInsured and bonded

Call (202) 600-6220

Do replacement windows have to meet the energy code?

Yes. When some or all of an existing window is replaced with a new product, sash and glass included, the energy code says the new unit must meet its U-factor and SHGC limits. When several windows are replaced, an area weighted average of the new units may be used to show they comply.

What the code says

The International Energy Conservation Code covers this in sections R503.1.1 and R503.1.1.1 of chapter 5.

  • New window or sash: meets the U-factor and SHGC limits.
  • Several units: an area weighted average of the new ones may be used.
  • Air leakage: the window air leakage rule also applies to the new work.
  • Exempt: storm windows over existing windows, and solar film on single pane glass.

Glass only repairs

If only a broken pane or a foggy double pane unit is being changed in a sound frame, ask your building department how they treat it, and ask us for low-e glass either way. Keep the new window labels until the inspection is done.

Read single pane vs double pane in an older home, or see double pane glass replacement for a free estimate.

Replacing windows or just the glass?

Send us photos and sizes for a free estimate, or call (202) 600-6220.