How much clear floor space does an ADA door need?

For a straight approach, the pull side needs a clear space 60 inches deep with 18 inches beyond the latch edge, and the push side needs 48 inches deep. On the push side, a door with both a closer and a latch also needs 12 inches beside the latch.

What the ADA standards say

The U.S. Access Board publishes the ADA accessibility standards. Table 404.2.4.1 sets the clear floor space at manual swinging doors.

  • Front, pull side: 60 inches deep, 18 inches beyond the latch.
  • Front, push side: 48 inches deep; add 12 inches beside the latch if the door has both a closer and a latch.
  • From the latch side: 24 inches beyond the latch, 48 inches deep to pull or 42 to push, plus 6 inches with a closer.
  • Floor: level, apart from a gentle slope and a compliant threshold.

Recessed doors and glass walls

If a wall or cabinet within 18 inches of the latch side sticks out more than 8 inches past the door face, the door counts as recessed and needs the front clearances. Glass office fronts can place doors tight to a side panel, so check that space first.

Read glass office partitions vs drywall, or see door closer repair for a free estimate.

Door closer too strong or failing?

Send us a photo for a free estimate, or call (202) 600-6220.