What SHGC does commercial glass need?

In climate zone 4, the commercial energy code caps unshaded fixed glass at a solar heat gain coefficient of 0.36 and operable glass at 0.33. Glass under a deep enough overhang or awning is allowed a higher figure, up to 0.58 fixed and 0.53 operable when the shade is deepest.

What the rule says

The commercial part of the International Energy Conservation Code covers this in Table C402.4 of chapter 4.

  • Little or no shade: 0.36 fixed, 0.33 operable.
  • Moderate shade: 0.43 fixed, 0.40 operable.
  • Deep shade: 0.58 fixed, 0.53 operable.
  • Skylights: 0.40 in zone 4.
  • How shade is measured: the projection factor of the overhang.

SHGC measures how much of the sun’s heat comes through. Lower numbers let less in.

Choosing the glass

Tinted or low-e coated insulating glass is how most storefronts reach these numbers, but the limit is on the rated unit, so ask for its labeled SHGC. If your storefront sits under a canopy, work out the projection factor first, since it may allow a clearer glass.