Open 24/7Licensed in VirginiaInsured and bonded

Call (202) 600-6220

Does replacing storefront glass have to meet the energy code?

Not when only the glass changes. The commercial energy code lists a glass only replacement in an existing sash and frame as a repair, which does not have to meet the rules for new construction. New envelope assemblies installed as part of an alteration, such as a new storefront system, must meet them.

What the rule says

The commercial part of the International Energy Conservation Code covers this in sections C503 and C504.2 of chapter 5.

  • Glass only: a repair, in the existing sash and frame.
  • New assemblies: new windows and storefront in an alteration meet the new construction rules.
  • Unchanged parts: the rest of the building does not have to be upgraded.
  • Baseline: an alteration can’t leave the building less compliant.

Work on undamaged parts needed to make a repair counts as part of the repair.

Glass or a new system

A broken pane in sound storefront framing can be replaced with matching glass as a repair. If the framing is failing and the whole system is replaced, the new units have to meet the U-factor, SHGC and air leakage limits, so ask for their ratings.

Read whether low-e glass is worth it, or see storefront glass repair for a free estimate.

Storefront pane broken?

Send us a photo for a free estimate, or call (202) 600-6220.