Open 24/7Licensed in VirginiaInsured and bonded

Call (202) 600-6220

Can one window miss the U-factor if others beat it?

Yes. The energy code lets an area weighted average of the windows and doors meet the U-factor limit, so a larger, better window can offset a weaker one. With tradeoffs, the average in climate zone 4 can be no worse than 0.48 for windows and 0.75 for skylights.

What the code says

The International Energy Conservation Code covers this in sections R402.3.1 and R402.5 of chapter 4.

  • Averaging: area weighted, across the fenestration products.
  • SHGC: averaging also allowed for products that are mostly glass.
  • Tradeoff ceiling, zone 4: 0.48 for vertical windows, 0.75 for skylights.
  • Dynamic glass: counted on its own, not averaged in.

A worked example

Take 100 square feet of window at 0.28 and 20 square feet at 0.38. The area weighted average is 28 plus 7.6, divided by 120, or about 0.297, which meets the 0.30 limit. The same math works for SHGC, as long as each product is mostly glass and none of it is dynamic glazing.

Read whether low-e glass is worth it, or see low-e glass for a free estimate.

Replacing only some windows?

Send us a photo and sizes for a free estimate, or call (202) 600-6220.