Can tinting smart glass meet the energy code?

Yes. Glass that tints on its own, which the energy code calls dynamic glazing, can meet the SHGC limit if its higher labeled SHGC is at least 2.4 times its lower one and it is controlled automatically in multiple steps. Dynamic glass is counted on its own and can’t be averaged with other windows.

What the code says

The International Energy Conservation Code covers this in section R402.3.2 of chapter 4.

  • Ratio: higher labeled SHGC at least 2.4 times the lower.
  • Control: automatic, in multiple steps.
  • Averaging: not allowed with other fenestration.
  • Exception: no ratio test if both the low and high SHGC already meet the limit.

The ratio uses the labeled values, so both must appear on the product label.

Zone 4 numbers

In climate zone 4 the SHGC limit is 0.40. Dynamic glass whose darkest and lightest labeled values both sit at or under 0.40 passes without the ratio test. Ask for both labeled values before ordering. The U-factor limit still applies to dynamic glass, 0.30 for new windows in zone 4.