How tall does a commercial door have to be?

At least 80 inches of clear opening height, under the building code rule for doors on the way out of a building. Door closers, overhead stops, power operators and magnetic locks are allowed a little lower, down to 78 inches above the floor. The same rule asks for at least 32 inches of clear width.

What the code says

The International Building Code sets door sizes in section 1010.1.1 of chapter 10.

  • Height: 80 inches clear at least.
  • Width: 32 inches clear, measured from the face of the open door to the stop, with the door at 90 degrees.
  • Below 34 inches: nothing may stick into the clear width.
  • From 34 to 80 inches: nothing may stick in more than 4 inches.
  • Hardware overhead: closers, stops, operators and magnetic locks may sit at 78 inches.

Checking the hardware

When a closer or overhead stop is replaced, measure from the finished floor to the lowest point of the new arm or body. It should read 78 inches or more. A magnetic lock or power operator added later follows the same limit.